19. Insert the two half wrenches that form the clamp into the exposed driver ring, with the offset dowel pins in the half wrenches located toward plate 1. Attach the screws to hold the half sections together. Then, remove the strain insulator, plate 2, and the threaded rods, leaving only the clamp against plate 1 still attached to the line. 20. Attach the inner conductor tool (#220335) around the broken inner conductor about 0.25 inch (6 mm) from the driver ring edge. Disengage the inner joint by rotating the broken conductor. During disengagement, hold the clamp stationary and use the inner conductor tool to turn the conductor.


Page 22 of 34 -- Page 23 of 34 -- Page 24 of 34