[Code of Federal Regulations]
[Title 47, Volume 1, Parts 0 to 19]
[Revised as of October 1, 1999]
From the U.S. Government Printing Office via GPO Access
[CITE: 47CFR18.309]

[Page 734-735]
 
                       TITLE 47--TELECOMMUNICATION
 
              CHAPTER I--FEDERAL COMMUNICATIONS COMMISSION
 
PART 18--INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT--Table of Contents
 
                     Subpart C--Technical Standards
 
Sec. 18.309  Frequency range of measurements.

    (a) For field strength measurements:

----------------------------------------------------------------------------------------------------------------
                                                             Range of frequency measurements
Frequency band in which device operates ------------------------------------------------------------------------
                 (MHz)                             Lowest frequency                    Highest frequency
----------------------------------------------------------------------------------------------------------------
Below 1.705............................  Lowest frequency generated in the    30 MHz.
                                          device, but not lower than 9 kHz.
1.705 to 30............................  Lowest frequency generated in the    400 MHz.
                                          device, but not lower than 9 kHz.
30 to 500..............................  Lowest frequency generated in the    Tenth harmonic or 1,000 MHz,
                                          device or 25 MHz, whichever is       whichever is higher.
                                          lower.
500 to 1,000...........................  Lowest frequency generated in the    Tenth harmonic.
                                          device or 100 MHz, whichever is
                                          lower.

[[Page 735]]


Above 1,000............................  ......do...........................  Tenth harmonic or highest
                                                                               detectable emission.
----------------------------------------------------------------------------------------------------------------

    (b) For conducted powerline measurements, the frequency range over 
which the limits are specified will be scanned.