Description
These hanger kfts and accessory kits are designed for
mounting vertical and horizontal runs of RADIAX slotted
coaxial cables. Each kit contains ten items. The kits are
used with the following cable sizes:
Hanger kit (10 pieces) |
Cable size and type |
Hanger spacing ft (m) |
209800-8 |
1/4" RX1-2, RX1-2RN |
3 (0.0) |
209800-10 |
1/4" RX1-2RNT; 3/8" RXL2-2, RXL2-2RN |
3 (0.9) 5 (1.5) |
209800-12 |
3/8" RXL2-2RNT |
5 (1.5) |
209800-15 |
1/2" RXL4-1, RXL4-1RN, RXL4-2, RXL-2RN, RXL4-3, RXL4-3RN |
5 (1.5) |
209800-17 |
1/2" RXL4-1RNT, RXL4-2RNT, RXL4-3RNT |
5 (1.5) |
209800-25 |
7/8" RXL5-1, RXL5-1RN |
5 (1.5) |
209800-28 |
7/8" RXL5-1RNT |
5 (1.5) |
209800-36 |
1-1/4" RXL6-1, RXL6-1RN |
7 (2.1) |
209800-40 |
1-1/4" RXL6-1RNT1, RXL6-1RNT |
7 (2.1) |
209800-47 |
1-5/8" RXL7-1, RXL7-1RN, RXL7-1RNT |
7 (2.1) |
Accessory kit (10 pieces) |
Use |
209795 |
Standoff for spacing hanger 2" from mounting surface |
|
209797 |
Flange inserts into hanger slot to accept 1/4"-20 threaded rod |
|
209798 |
Adaptor for attaching 3/8"-16 threaded rod to flange |
|
209799 |
Threaded stud, 1/4" 20 x 1/2", for attaching flanges of two hangers together |
|
223160 |
Adaptor for attaching hanger to strut |
|
|
Spread jaws and insert cable
|
Firmly push to engage first or
second locking tooth of outer jaw
|
Pressure at these points from cable forces hanger closer
|
Hanger closure at first locking tooth
|
Notice
The installation, maintenance, or removal of antenna systems requires qualified, experienced personnel.
Andrew systems should be inspected once a year by qualified personnel
to verify proper installation,
maintenance, and condition of equipment.
Andrew disclaims any liability or responsiblity for the