Installation Instructions
Self-Locking Hanger Kits
for HELIAX® Coaxial Cable
Bulletin 237117

Revision B

Description

These hanger kfts and accessory kits are designed for
mounting vertical and horizontal runs of RADIAX slotted
coaxial cables. Each kit contains ten items. The kits are
used with the following cable sizes:

Hanger kit
(10 pieces)
Cable size and type Hanger
spacing
ft (m)
209800-8 1/4" RX1-2, RX1-2RN 3 (0.0)
209800-10 1/4" RX1-2RNT;
3/8" RXL2-2, RXL2-2RN
3 (0.9)
5 (1.5)
209800-12 3/8" RXL2-2RNT 5 (1.5)
209800-15 1/2" RXL4-1, RXL4-1RN,
RXL4-2, RXL-2RN,
RXL4-3, RXL4-3RN
5 (1.5)
209800-17 1/2" RXL4-1RNT, RXL4-2RNT,
RXL4-3RNT
5 (1.5)
209800-25 7/8" RXL5-1, RXL5-1RN 5 (1.5)
209800-28 7/8" RXL5-1RNT 5 (1.5)
209800-36 1-1/4" RXL6-1, RXL6-1RN 7 (2.1)
209800-40 1-1/4" RXL6-1RNT1, RXL6-1RNT 7 (2.1)
209800-47 1-5/8" RXL7-1, RXL7-1RN,
RXL7-1RNT
7 (2.1)
Accessory
kit
(10 pieces)


Use
209795 Standoff for spacing
hanger 2" from
mounting surface
H117-1
209797 Flange inserts into
hanger slot to accept
1/4"-20 threaded rod
H117-2
209798 Adaptor for attaching
3/8"-16 threaded rod
to flange
H117-3
209799 Threaded stud, 1/4" 20
x 1/2", for attaching
flanges of two hangers
together
H117-4 H117-5
223160 Adaptor for attaching
hanger to strut
H117-6
Hanger
Spread jaws and
insert cable
H117-8
Firmly push to engage first or
second locking tooth of outer jaw
H117-9
H117-13
Pressure at these points from
cable forces hanger closer
H117-14
Hanger closure at first
locking tooth

Notice
The installation, maintenance, or removal of antenna systems requires qualified, experienced personnel.
Andrew systems should be inspected once a year by qualified personnel
to verify proper installation,
maintenance, and condition of equipment.

Andrew disclaims any liability or responsiblity for the
results of improper or unsafe installation practices.

Page 1 of 2 -- Page 2 of 2