Installation Instructions MACXLineTM Rigid Coaxial Transmission Lines |
Bulletin 237086A |
Thoroughly Before Assembly Vertical Installation The inner connector insulator and protective cover provide support for the inner conductor of each line section during the hoisting operation. Note: Do not attach hoisting sling to line section flanges. Refer to Figure 1. Remove protective cover from end of line section and retain supplied "O" ring seal. Note: One "O" ring is supplied per line section and may be located under either protective end cover or in a separately supplied hardware kit. |
Insert supplied liner connector into bellows end of inner conductor. Inner conductor may be pulled slightly from outer conductor while inserting inner connector assembly. Note: Do not apply twisting force on bellows while engaging inner connector assembly. Apply thin coating of silicone grease to supplied "O" ring seal to temporarily secure "O" ring in position during assembly. Note: Ensure both seal and flange groove are free of dirt to ensure pressure tight seal. Bellows end of line, as designated by red arrow label on outer conductor, must be installed toward antenna. Note: Bottom protective end cap may be temporarily secured to flange while hoisting transmission line assembly. Remove and discard protective cover from end of previous line section. Align flange pins with corresponding flange alignment holes and join mating sections. Firmly push line and inner connector insulator seats properly in mating flanges. Install and alternately snug mounting hardware at 180° intervals while maintaining a uniform gap between flanges. Perform final torquing sequence in a circular pattern. Do not overtighten. When properly installed, a small uniform gap should be noted around flange circumference. Note: The use of an anti-seize compound on all stainless hardware is recommended to prevent galling. |