Installation Instructions Types RLA300-14, RLA600-14, RLA800-14, and RLA800-14 Lateral Braces for 3-1/8", 6-1/8", 7-3/16" and 8-3/16" Transmission Lines |
Bulletin 237085 Revision B |
A lateral brace is required on the lower portion of the vertical
transmission line run to restrict lateral motion while allowing
for vertical and horizontal line movement. The lateral brace kit includes a hanger casting, adjustable clamps, and mounting hardware. Clamp the lateral brace assembly to the vertical transmission line run above the 90° miter elbow as shown. Note: Align the 3/8" eyebolt with existing hole in tower if possible. Caution: Contact th tower manufacturer for applicable safety regulations regarding the drilling of any holes in tower sections. If no holes are available, use Type 13555A adaptors for angle tower members and Type 13550 adaptors for round tower members. |
Adjust the brace assembly to a position of the least amount of
strain and bolt directly to the tower leg as shown using the
supplied mounting hardware. Andrew disclaims any liability or responsibility for the results of improper or unsafe installation practices. |
Andrew Corporation |
Telephone: 708-349-3300 |
Customer Service, 24 hours: U.S.A. * Canada * Mexico: 1-800-255-1479 |
10500 West 153rd Street |
FAX (U.S.A.) 1-800-349-5444 |
U.K. 0800 250055 * Republic of Ireland: 1 800 535358 |
Orland Park, IL U.S.A. 60462 |
Internet: http://www.andrew.com |
Other Europe: +44 1592 782612 |