4. Mount Outer Body. Add the large O-ring to the clamping nut. Apply a thin coating of silicone grease to the outer surface of the O-ring and the outer chamfer surface of the outer body. Keep all connector threads free of grease. 5. Position and Heat Shrink Tube. Slide the shrink tube to a point 7/8" (22 mm) beyond the cable end of the clamping nut. Apply heat around the tube to shrink it just enough for a tight seal--do not overheat the tube! Heating may be done with an electric heat gun, propane torch, or butane torch. |
Andrew Corporation |
Telephone: 708-349-3300 |
Customer Service, 24 hours: U.S.A. * Canada * Mexico: 1-800-255-1479 |
10500 West 153rd Street |
FAX (U.S.A.) 1-800-349-5444 |
U.K. 0800 250055 * Republic of Ireland: 1 800 535358 |
Orland Park, IL U.S.A. 60462 |
Internet: http://www.andrew.com |
Other Europe: +44 1592 782612 |