The adaptor may be installed on either
angled or horizontal tower bracing members
at the discretion of the installer. However, the
bracing pattern of the tower may affect the
choice of adaptor-attaching hardware.
Adaptor installation onto a tower using a
back-to-back bracing configuration will require
the use of clamps (supplied as part of the
Angle Adaptor Kit) as attaching software.
Installation of Type 206929-1008 (eight-run)
adaptor on an X-braced tower will require the
use of clamps if the positioning of the adaptor
requires its placement at the point which the
two X-braced tower angles intersect. An
eight-run support can be achieved with the
use of the J-Bolt Hardware kit, by installing
two 206929-1004 (four-run) adaptors on either
side of the intersection point of the X-braced
tower angles.
READ THE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLATION

1.0 J-Bolt Hardware Kit

Assembly/Installation

1.1 Refer to Figure 2. Loosely install 5/16"
captivating bolt, flat washer, lock washer and
nut onto each adaptor as shown.

1.2 Assemble appropriate number of J-bolts
required for the attachment of corresponding
adaptors using 3/8" flat washer, lock washer
and nut as shown.


Page 1 of 4 -- Page 2 of 4 -- Page 3 of 4